Introduction to Mars6 High-throughput Closed Microwave Digestion System (Microwave Digestion System)

American CEM company has been known as microwave chemistry founder, has 11 times won the R & D100 Award, the champion in the analytical instrument industry, CEM is the only professional microwave manufacturers of microwave equipment design and manufacture of ISO-9001 certificate, developed and owned by Microwave Chemistry industry 90% (more than 300) patented technology, as the world's largest professional microwave chemistry equipment manufacturers, whose products accounted for world market share of 80% +, almost all of microwave chemistry international standard methods, such as: EPA, AOAC, ASTM, NIST, etc. are jointly developed by CEM and related institutions and recommended to a wide range of application chemists.

The Mars6 high-throughput closed microwave digestion system ( microwave digestion instrument ) is the only microwave sample pretreatment instrument that has won the R&D100 award , and has achieved the unremitting pursuit of the safety, scientific and high efficiency requirements of the laboratory chemist for the closed microwave chemical reaction system.  

Elemental analysis of hidden errors can cause terrible quality and safety accidents and huge economic losses, but few people know that 70% of analysis failures are actually derived from sample preparation. In order to ensure the correctness and safety of elemental analysis, it must be guarded against In the first place, choose the best and most reliable microwave digestion instrument brand - CEM Mars 6

Select Mars6 high throughput closed microwave system grounds (microwave digestion) digestion:

1. The scientific nature of the analysis results : Exhaust ( loss element ) is contrary to the basic analysis requirements of various standards such as EPA . Therefore, CEM adopts a safe energy-enclosed patented design to prevent element loss and leakage caused by exhaust gas , ensuring AA, ICP. , ICP-MS and other elemental analysis results are accurate and reliable ;

2. The authoritative standard methods: the instrument is to develop EPA3015,3051,3052,3546 AOAC ASTM standard methods like;

3. Convenient , fast and efficient : ( There are a large number of customers actually applied ) Batch processing up to 40 independent closed samples , 4 times that of general microwave digestion instruments . Reagent dosage only needs 5-10mL, low blank , no pollution ;

4. Safe and fast cooling method : turbulent air-cooled design and thermal superconducting aerospace fiber casing , the only user-friendly design with no-transport after digestion, fast in-situ cooling control and safety indication , greatly reducing potential operational risks ;

5. Advanced safety design concept : Exclusive use of patented aerospace composite fiber explosion-proof casing , with three-dimensional directional explosion-proof technology , multiple active and passive safety measures to ensure personnel safety ;

6. Professional electromagnetic protection design : Execute professional electromagnetic load ( analog microwave chemical special application ) electromagnetic safety test , the only high-end microwave leakage protection standard.

main feature

Mars6 high throughput closed microwave digestion system (microwave digestion) is the exact chemical reaction process comprising the microwave to accelerate the reaction control system, control, display and operating system integration integrated, reliable machine design against corrosion, save space, while an instrument machine can be used to analyze a sample of the chemical digestion, extraction, proteolysis, concentrated, dried, organic / inorganic synthesis chemistry experiments, chemical process simulation and test data of various conditions of microwave chemistry applications.

The Mars6 high-throughput closed microwave digestion system ( microwave digestion ) also has the following features :

1. One Touch one-button intelligent integration : It can automatically identify the type, quantity and position of the reaction tank in the reaction chamber, and automatically detect the installation of the temperature control system. Subsequently, according to the characteristics and equivalent of the sample, the application method database is automatically retrieved, and the automatic energy optimization data matching calculation is performed. The whole process intelligent control does not need to be set, but at the same time, the whole process of temperature, pressure and power adjustment curves is displayed, 0-40 cans. The target tracks the real-time temperature status display.

2. PowerMAX Microwave Dynamics : PowerMax optimizes the kinetic energy mode with a specially designed bidirectional vertical waveguide cavity. Dynamically matched power emissions correspond to real-time reaction process changes, making it easy to cope with more difficult sample reactions.

3. iPad Video dynamic video / sound system : MARS6 is full of technology fun, people-oriented, built-in library of all scientific application guidance methods, carefully prepared a variety of text video recording of professional training courses.

4. Intelligent expert system : 100 kinds of international standard application methods of memory , users can also edit, store, modify and delete the application methods of specific samples ;

The safety relief way: a non-metallic polymeric material and automatic pressure relief rupture disk patented double safety mechanism to ensure safe operation and integrity of the sample (guaranteed RECOVERY);

6. Multiple active safety control : patented non-pulsed automatic microwave energy control , accurate temperature / pressure real-time monitoring , full tank temperature / pressure monitoring , power frequency matching design and microwave field resonance equalization technology ensure precise control of the reaction process ;

7. Multiple Passive Security: Security Patent high pressure jacket aerospace composite fiber (vertically oriented proof design), automatic safety door sensors and automatically cut off the microwave source and multiple security mechanisms in the abnormal situation, to ensure safety;

8. Batch is greater: (a large number of customers have practical applications) high pressure vessels up to 40 samples / batch, and all samples independently sealed to ensure no cross-contamination and sample loss.  

Mars6 high-throughput closed microwave digestion system ( microwave digestion ) reaction control system ( optional according to application )

1. Dual-beam multi-target temperature control system Dual IR, real-time detection control and display all the temperature and curve in the microwave digestion reaction tank , the range : 10-330 °C ;

2. High-frequency fiber temperature control system RTP-330 Plus, real-time detection and control and display the temperature and curve in the microwave digestion reaction tank , the range : -40-330 °C ;

3. High-frequency multi-target temperature control system DuoTemp, real-time detection control and display the temperature and curve of all microwave digestion reaction tanks , automatically monitor and adjust the most severe sample parameters , and display the controlled sample position number , can set the allowable error 0- 5 °C ;

4. Full tank pressure control system ReactiGuard, real-time monitoring of all microwave digestion reaction tank pressure , overpressure automatic adjustment / stop microwave emission and automatic alarm , range : 0-1500psig;

5. Piezoelectric crystal pressure control system ESP-1500 Plus, real-time detection control and display the pressure and curve in the microwave digestion reaction tank , range : 0-1500psig;

6. Other testing options : UP Sensor, S Sensor, etc.

Mars6 high-throughput closed microwave digestion system ( microwave digestion ) reaction tank assembly ( optional according to application )

Inner tank material: PFA , TFM , quartz, etc.;

Outer tank material: aerospace composite material;

Maximum temperature: 260 °C, 330 °C optional;

Maximum pressure: 800 psi , 1500 psi , 2200 psi optional;

Volume: 3ml , 7ml , 10ml , 25ml , 50ml , 75ml , 100ml , 110ml optional;

Batch volume: 0-40 samples / batch Optional.

Industrial Laser Distance Sensor

Industrial Laser Distance Sensor, we also call it secondary development laser distance module, which support TTL level and CMOS. The laser range sensor can be widely used in professional surveying, mapping, construction, robots, hunting arrows, industrial monitoring and automated measurement applications in electricity, transportation, etc. Our laser distance module supports data communication with RS232, USB with a simple adapter. The results of laser distance sensor can be evaluated with Arduino. We are always looking ahead, hoping we can make every measurement simple in life!

Industrial Laser Distance Sensor

Parameters of M703A:

Accuracy

±1 mm (0.04 inch)

Measuring Unit

meter/inch/feet

Measuring Range (without Reflection)

0.03-150m

Measuring Time

0.1~3 seconds

Laser Class

Class II

Laser Type

635nm, <1mW

Size

72*40*18mm (±1 mm)

Weight

About 21g

Voltage

DC2.0~3.3V

Electrical Level

TTL/CMOS

Frequency

10Hz

Operating Temperature

0-40 ℃ (32-104 ℉ )

Storage Temperature

-25~60 ℃ (-13~140 ℉)

Laser Distance RS232,Arduino Distance Module,Laser Module RS232

Chengdu JRT Meter Technology Co., Ltd , https://www.jrt-measure.com