   MODEL:CMS8000  Brand:CONTEC USA warehouse:Chicargo
Functions
Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
1)ECGÂ Â Heart rate(HR)
     ECG waveform
     Arrhythmia and ST-segment analysis
2)RESPÂ Â Respiration rate(RR)
     Respiration waveform
3)SpO2Â Â Oxygen saturation(SpO2)
     Plethysmogram(PLETH) waveform
     Pulse rate(PR)
     Bar graph
4)NIBPÂ Â Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5)TEMPÂ Â T1, T2, TD
6)IBP(optional)Â CH1:SYS,DIA,MAP
CH2:SYS,DIA,MAP
IBP waveform
7)CO2(optional)Â EtCO2
InsCO2:Inspired Minimum CO2
AwRR:Air Way Respiration
It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP
measurement, alarm event marking and drug concentration calculation, etc.
Performance
Â
 ECG
Multi-parameter Portable Cardiac Patient Monitor FDA
Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, dual-channel 3-lead, single-channel Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
HR:
Measurement and alarm range: 15~350 bpm
Accuracy: ±1 % or ±1 bpm, whichever is greater Alarm accuracy: ± 2 bpm Resolution: 1 bpm ST-segment monitoring: Measurement and alarm range: -2.0 mV ~ +2.0 mV Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Pacemaker: yes
RESP
Method: R-F(RA-LL) Impedance
Respiration rate:Measurement and alarm range: 0~150 rpm Resolution: 1 rpm Measurement accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
NIBP
Method: Oscillometry
Mode: Manual/AUTO/STAT Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes Measurement period in STAT mode: 5 minutes Measurement and alarm range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff pressure accuracy: ±3 mmHg Measurement accuracy:
Maximal mean deviation: ±5 mmHg
Maximal standard deviation: 8 mmHgOver-pressure protection:
Adult mode: 297±3 mmHg
Pediatric mode: 240±3 mmHg
Neonatal mode: 147±3 mmHg
Spo2
Measurement and alarm range: 0 ~ 100%
Resolution: 1% Measurement accuracy: 70%~100%: ±2%; 0%~69%: unspecified
PR
Measurement and alarm range: 30 ~ 250 bpm
Measurement accuracy: ±2 bpm or ±2%, whichever is greater
TEMP
Channel: dual-channel
Measurement and alarm range: 0 ~ 50ºC Resolution: 0.1 ºC Accuracy: ±0.1 ºC
EtCO2
Method: Sidestream or Mainstream
Measuring Range: 0~150mmHgResolution:0~69 mmHg, 0.1 mmHg
     70~150 mmHg, 0.25 mmHgAccuracy:0~40 mm Hg ±2 mm Hg
    41~70 mm Hg ±5%
    71~100 mm Hg ±8%
    101~150 mm Hg ±10%AwRR Range: 2~150 rpm AwRR Accuracy: ±1BPM Apnea Alarm: Yes
IBP
Channel: dual-channel
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring and Alarm Range: -10~300 mmHg Resolution 1 mmHg Accuracy: ±2% or 1mmHg, whichever is greater Power supply: 100-240V~, 50/60Hz Safety classification: Class I, type CF defibrillation-proof applied part
Contec Cms8000 Cheap Multi-Parameter Beside Portable Cardiac ECG Patient Monitor FDA
Model NO.: CMS8000
Product Name: Multi-Parameter Portable Cardiac Patient Monitor F
Multi-Parameters: ECG, SpO2, NIBP, 2-Temp, Pr
Optional: 2-IBP, Etco2, and Thermal Printer
Multi-Language: Yes
USA Warehouse: Chicargo
Trademark: CONTEC
Transport Package: Carton
Specification: 43.1*35.3*42.5(cm)
Origin: Hebei, China
HS Code: 9018193010
      Multi-parameter Portable Cardiac Patient Monitor FDA