I. Environmental management 1. Do a good job in the management of personnel and various items in the laboratory. 2. Clean labs should not use powdered gloves. 3. It is strictly forbidden to fold all kinds of cloth dressings in the experiment room or bring personal items and books to the laboratory. Second, clean air conditioning management 1. All cleaning work should be done with a damp cloth during the operation of the purification system. 2. All kinds of instruments and equipment that enter the experiment room should be installed and cleaned before entering. 3. Immediately after the end of the experiment, clear, wipe, and organize all kinds of items. 4. Clean and disinfect the isolation shoes worn by the staff. 5. Thoroughly wipe, clean and maintain all equipment and ground every week. 6. Clean the return air outlet once a week. The coarse filter and the medium efficiency filter are cleaned once a month. 7. Disinfect the coarse filter, medium efficiency filter, and return air net with a 500 mg/L chlorine disinfectant wet wipe every 2 weeks. 8. Sampling the air and equipment surface of the clean laboratory part every month for bacterial culture, and testing the temperature and humidity once. The results are registered and filed. Third, monitoring management 1. The laboratory infection control team will do monthly rectification of monitoring, sampling and monitoring of air, hand, surface, disinfectant, etc. 2. The air cleanliness monitoring adopts the “multi-point control sampling†detection method. The static method is the main one, and the dynamic method is the supplement. Fourth, equipment management 1. The equipment department will check the air conditioner display data on the control panel every day and check the operation of the air conditioning system every week. 2. The equipment department specializes in maintenance work. Establish a maintenance log. 3. At least 1 hour before the operation, the laminar flow should be opened to maintain the low-speed operation state, and the high-speed operation should be adjusted 30 to 40 minutes before the experiment. 4. In the experimental room that has not been used for a long time, the air supply filter should be cleaned first and should be turned on at least 3 hours before starting. 5. Do a good job in the operational safety management of the laminar flow laboratory. Personnel should be familiar with the use of fire equipment and the location of safe passages. 6. After the experiment is completed, the cleaning is completed, and all the appliances must be turned off after the person leaves. Tylosin Injection,Veterinary Injection,Inj Oxytetracycline,Ivermectin 1 Injectable NINGBO VOICE BIOCHEMIC CO. LTD , https://www.medicine-voice.com