Our ELISA kit quality assurance, excellent quality, affordable, is your first choice for biological experiments, if you need to contact our sales staff. This reagent is for research use only: This kit is used to determine the content of mouse pyrophosphate farnesyl ester (FPP) in mouse serum, tissue and related liquid samples. Experimental principle : The kit uses a double antibody sandwich assay to determine the level of mouse pyrophosphate farnesyl ester (FPP) in the specimen. The microporous plate was coated with purified mouse farophosphate pyrophosphate (FPP) antibody to prepare a solid phase antibody, and the farnes of the coated mAb were sequentially added with farnesyl pyrophosphate (FPP), followed by HRP labeling. The farnesyl pyrophosphate (FPP) antibody binds to form an antibody-antigen-enzyme-labeled antibody complex, which is thoroughly washed and then added to the substrate TMB for color development. TMB is converted to blue under the catalysis of HRP enzyme and converted to the final yellow color by the action of an acid. The color depth is positively correlated with farnesyl pyrophosphate (FPP) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of mouse pyrophosphate farnesyl ester (FPP) in the sample was calculated from a standard curve. Kit composition : Kit composition 48 hole configuration 96-well configuration save Instruction manual 1 copy 1 copy Sealing film 2 pieces (48) 2 pieces (96) sealed bag 1 1 Enzyme label coated plate 1×48 1×96 Store at 2-8 ° C Standard: 90pg/mL 0.5ml × 1 bottle 0.5ml × 1 bottle Store at 2-8 ° C Standard dilution 1.5ml × 1 bottle 1.5ml × 1 bottle Store at 2-8 ° C Enzyme standard reagent 3 ml × 1 bottle 6 ml × 1 bottle Store at 2-8 ° C Sample diluent 3 ml × 1 bottle 6 ml × 1 bottle Store at 2-8 ° C Developer A solution 3 ml × 1 bottle 6 ml × 1 bottle Store at 2-8 ° C Developer B solution 3 ml × 1 bottle 6 ml × 1 bottle Store at 2-8 ° C Stop solution 3ml × 1 bottle 6ml × 1 bottle Store at 2-8 ° C Concentrated washing solution (20ml × 20 times) × 1 bottle (20ml × 30 times) × 1 bottle Store at 2-8 ° C Sample processing and requirements : 1. Serum: The blood is naturally coagulated at room temperature for 10-20 minutes and centrifuged for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if precipitation occurs during storage, it should be centrifuged again. 2. Plasma: EDTA, sodium citrate or heparin should be selected as anticoagulant according to the requirements of the specimen. After mixing for 10-20 minutes, centrifuge for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if a precipitate forms during storage, it should be centrifuged again. 3. Urine: Collect with a sterile tube and centrifuge for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if a precipitate forms during storage, it should be centrifuged again. The chest and ascites and cerebrospinal fluid are referred to. 4. Cell culture supernatant: When detecting secreted components, collect them with a sterile tube. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. When the components in the cells were detected, the cell suspension was diluted with PBS (pH 7.2-7.4), and the cell concentration reached about 1 million/ml. By repeated freezing and thawing, the cells are destroyed and the intracellular components are released. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again. 5. Tissue specimen: After cutting the specimen, weigh the weight. Add a certain amount of PBS, pH 7.4. It was quickly frozen and stored in liquid nitrogen for use. The specimen still maintains a temperature of 2-8 ° C after melting. A certain amount of PBS (pH 7.4) was added, and the specimen was homogenized by hand or homogenizer. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. One part of the package is to be tested, and the rest is frozen for use. Steps Precautions: 10. In the case of an English manual, the English manual shall prevail. Calculation : Taking the concentration of the standard as the abscissa and the OD as the ordinate, draw a standard curve on the coordinate paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; multiply by the dilution factor; or use the concentration of the standard Calculate the linear regression equation of the standard curve with the OD value, substitute the OD value of the sample into the equation, calculate the sample concentration, and multiply by the dilution factor, which is the actual concentration of the sample. Kit performance: 1. The linear regression coefficient of the sample and the expected concentration correlation coefficient R value is 0.95 or more. 2. Within and within the batch should be less than 9% and 11% respectively examination range: 2pg/mL -80 pg/mL Storage conditions and expiration date: 1. Kit storage: 2-8 ° C. 2. Validity: 6 months
Laser distance measure is a very convenient
tool for various types of applications in industries, construction and house decoration.
Laser distance meter is a very useful device which gives accurate measurement
of distance, area and volume especially in large areas such as rooms,
apartments, buildings, real estates, factories, warehouses, infrastructures, gardens,
roads, and many other applications requiring accurate results for distance ,
area and volume measurement.
Trade your heavy tape measure for laser
rangefinder, which let you simply take measurements with one hand. No matter
your job, the laser rangefinder will help you measure much farther, with
greater accuracy and in more situations, saving you money and time.
Specification:
Product
Model:
JX40
Accuracy:
±1.5mm (0.06
inch)
Measuring
Unit:
metre/inch/feet
Measuring
Range:
0.03~40m
(0.01 to 131 ft)
Measuring
Time:
0.1~4
seconds
Laser Class:
Class II
Laser Type:
635nm,
<1mW
Waterproof
& Dustproof :
IP54
Auto Laser
Off:
60 seconds
Automatic
Power-off:
480
seconds(8 minutes)
Lighting:
white LED
Datum
Option:
Can choose
Front edge or end piece edge as datum
Battery
Status:
Y
Signal
Strength Display:
Y
LCD display:
2 inch large
screen
Display
illumination and multi-line display:
Max
2 displays
Data Memory:
Y (allow 20
values)
Backlight
display:
Y
Continuous
Measurement:
Y
Min/max
Measurement:
Y
Addition/Subtraction(Distance/Area/Volume):
Y
Area/Volume/Pythagoras
Measurement:
Y
Battery
Type:
AAA alkaline
battery(2*1.5v )
Weight:
about
80g
Dimensions(L*W*H):
4*2*11.5cm
Auto
correction and error report technology:
Y
Operating
Temperature:
0-40 ℃(32-104 ℉ )
Storage
Temperature:
-20~60 ℃
(-4~140 ℉)
Laser Distance Meter,Laser Distance Measure,Laser Rangefinder,Laser Distance Gauge Chengdu JRT Meter Technology Co., Ltd , https://www.infrareddistancesensor.com